Speed Controller SPD-24500R-V2 Installation and Wiring |
|
Rated Voltage | 24 Volts | Rated For Motors | Up To 500 Watts |
Maximum Current | 30 Amps |
Rated For Chargers | Up To 3 Amps |
Conversion Efficiency | 95% |
Under Voltage Protection | 20.5 Volts |
Recommended Fuse Size | 40 Amps |
Dimensions | 4-3/8" L x 2-5/8" W x 1-5/8" H |
Under Voltage Battery Protection:
When the battery pack falls below a specific Voltage the controller
turns the motor off preventing over discharging of the battery pack
which extends the battery packs lifespan. (The cutoff value is
approximately 20.5 Volts ± 1.0 Volts) Motor Cut-Off During Braking: When the brakes are engaged the brake switch signals the controller to turn off the motor. Note About Connectors: The Charger Port, Brake Light, and Indicator connectors with black and red wires have printed labels on them that say what their functions are. Two of these labels are facing down and not visible in the photograph of the controller shown above. |
*Power Connector
Mating Connector Item # CNX-50 |
|
|
Motor
Connector
Mating Connector Item # CNX-50 |
Required Connection |
|
Throttle
Connector
Mating Connector Item # CNX-52 |
Required Connection |
|
Key
and Forward/Reverse Switch Connector
Mating Connector Item # CNX-52 |
Required Connection |
|
Battery Charger Connector Mating Connector Item # CNX-51 |
~Optional Connection |
|
Brake
Lever
Switch Connector Mating Connector Item # CNX-51 |
~Optional Connection |
|
Brake
Light Connector Mating Connector Item # CNX-51 |
~Optional Connection |
|
Power
Light Connector Mating Connector Item # CNX-51 |
~Optional Connection |
Example of How To
Wire Power and Reverse Switches |
*The power connector
should be the last connection made. *Fuse or circuit breaker protection is required between speed controller and battery pack. ~Optional Connections do not need to be hooked up for the speed controller to operate. |